Airyx OPC‑UV3‑DL‑301 Open Path Ammonia Analyzer
CONTACT‑FREE NH₃ MEASUREMENTS OVER OPEN PATHS FROM 20 TO 150 M.
Description
The Airyx OPC‑UV3‑DL‑301 is an open path ammonia analyzer designed for contact‑free NH₃ monitoring over distances from 20 to 150 meters. By measuring along an open beam through the target area, the system avoids surface losses in sampling lines and provides highly representative, path‑averaged concentration data.
With its multi‑path capability and automated alignment, the analyzer can sequentially monitor multiple retroreflector paths, enabling spatially resolved ammonia measurements. This makes the OPC‑UV3‑DL‑301 suitable for agricultural emission studies, industrial fence‑line monitoring, and environmental air quality applications.
The system uses Differential Optical Absorption Spectroscopy (DOAS) in the UV range, powered by a stable deuterium lamp and a compact, temperature‑stabilized spectrometer. The motorized telescope head allows remote alignment and multi‑path routing, minimizing setup time and on‑site aintenance.
As a long‑path UV DOAS ammonia monitoring system, it eliminates the need for sampling lines and avoids NH₃ surface losses, ensuring stable and accurate open path gas monitoring even in challenging environments.
Product Description
Key Features
Accurate gas detection
Measures NH₃, NO and SO₂ using established UV DOAS technology.
No sampling lines and no surface losses due to contact‑free remote sensing.
Compact and flexible system
One analyzer supports multiple measurement paths using a motorized telescope and retroreflectors.
Easily adapts to varying site layouts.
Rugged and mobile
Weatherproof IP64 housing with internal heating and dew‑point monitoring ensures robust operation in harsh environments.
Plug‑and‑play setup
Motorized self‑alignment enables fast deployment and minimal on‑site adjustment.
Calibration‑free operation
DOAS technology requires no calibration gas bottles and shows no long‑term drift, reducing maintenance and operating costs.
Applications
- Air quality and workplace safety around ammonia sources
- Agricultural NH₃ emission monitoring from barns and fields
- Industrial emission and process control for NH₃ and related gases
- Fence‑line monitoring at industrial or agricultural sites
- Spatial NH₃ distribution analysis over open paths
- Real‑time ammonia concentration measurement over 20–150 m
Frequently Asked Questions
What is an open path ammonia analyzer?
An open path ammonia analyzer measures NH₃ concentrations along a free air path
between an instrument and a reflector. This contact‑free approach avoids sample
line losses and provides representative average concentrations over distances from
20 to 150 m.
Which gases can the OPC‑UV3‑DL‑301 detect?
The system is optimized for NH₃ and can also measure NO and SO₂ using UV DOAS technology.
For which applications is the system best suited?
Typical applications include agricultural ammonia emission monitoring, fence‑line monitoring,
industrial emission control and environmental air quality research.
Does the analyzer require calibration gases?
No. DOAS is a calibration‑free technique and does not require calibration gas bottles,
which simplifies operation and reduces running costs.
What distances can the OPC‑UV3‑DL‑301 cover?
The system supports real‑time ammonia concentration measurement over open paths
between 20 and 150 meters using a retroreflector setup.
TECHNICAL DETAILS
| Parameter | Specification |
|---|---|
| Optics | Mirror telescope, 300 mm focal length |
| Detectable Gases | NH₃, NO, SO₂ |
| Limit of Detection (at 100 m path length, 5 min averaging) |
1 ppb (NH₃), 4 ppb (NO), 5.5 ppb (SO₂) |
| Path Length | Up to 150 m (retroreflector) |
| Time Resolution | Down to 1 minute |
| Compact Spectrometer | 190–310 nm spectral range, temperature stabilized |
| Motorization | Azimuth 0°–360°, Elevation −40° to 75° |
| Housing | IP64, internal heating, dew‑point monitoring |
| Control Unit | Integrated embedded PC (Windows 10 IoT) |
| Temperature Control | Active heating & cooling |
| Additional Sensors | Ambient temperature, pressure, housing dew point |
| Interfaces | LAN, WiFi, internal storage |
| Power Supply / Consumption | 24 V, max. 80 W |
Interested in open‑path ammonia monitoring?
Contact us for a quote or technical consultation.
FOR DIRECT CONTACT SEE FORM BELOW.
EUROPE
FRANCE:
MEGATEC SAS
Immeuble Homère, Les Algorithmes
91190 Saint-Aubin, France
Phone: + 33 1 69 35 58 00
Website: https://www.megatec.fr/
Contact: https://www.megatec.fr/contact
Contact person: Fabrice Losbar
SLOVAKIA, CZECH & LITHUANIA:
ENVItech Bohemia s.r.o.
Ovocná 34
161 00 Praha 6
Czech Republic
Webite: ENVItech Bohemia s.r.o.
Contact: Contact
SPAIN & PORTUGAL:
GREEN LIGHT RESEARCH SLU
Airyx products at Green Light Research:
ICAD NOx analysators
ICAD HONO/NO2 anaylsator
Open Path remote sensing
SkySpec remote sensing
ITALY:
LUCHSINGER SRL
Website: http://www.luchsinger.it/
Airyx Products | Luchsinger
UNITED KINGDOM & IRELAND:
CURA TERRAE AIR LTD
(FORMERLY ENVIRO TECHNOLOGY SERVICES LTD)
Unit B1, Kingfisher Business Park, London Road,
Stroud, Gloucestershire, GL5 2BY, UK
Phone: +44 (0) 1453 733200
Website: www.et.co.uk
NO₂/NOx/NO Analyser High Grade Version (ICAD 200DL) | ET
AirYX Plume Chasing – NO2 / NOX / NO ICAD In Situ Monitor | ET
AirYX HONO / NO2 Analyser (Model ICAD 200L) | Enviro Technology Services (et.co.uk)
NETHERLANDS, BELGIUM, LUXEMBOURG, DENMARK, SWEDEN, NORWAY:
THE DUTCH SCIENTIST
Kardinaal van Rossumplein 11
5211 RV ‘s-Hertogenbosch
The Netherlands
Phone: +31 629 437 116
Website: www.thedutchscientist.com
FINLAND:
HNU NORDION
Atomitie 5 B 600371, HELSINKI, FINLAND
Phone: +40 745 6225
Website: https://hnunordion.fi/
GREECE:
Polaris Environment Ltd
Complete Environmental Solutions
44 Lagoumitzi Str, 11745 Athens, Greece
Attn. Grigoris Nikolidakis
Phone: +306975906253
Website: www.polaris-environment.gr
ROMANIA:
APEL LASER
Mogosoaia, Strada Vanatorilor nr. 25, cod 077135, jud. Ilfov, Romania
Phone: +40 21 31 70 910
Website: Apel Laser » Lighting the Future
BULGARIA, SERBIA, NORTH MACEDONIA, ALBANIA, MONTENEGRO, SLOVENIA, CROATIA, TURKEY:
STABO-Tech. Ltd.
ul. Dimitar Naumov, 88
6000 Stara Zagora, Bulgaria
Phone: 0039 349 5440483
Website: http://stabo-tech.eu/
ASIA
INDIA:
M&G analyser systems
501,Zenith commercial complex
28/2 Near Agricultural college.
Shivaji Nagar, Pune -411007, India
Website:
:: M & G Analyser Systems | Pune ::
Contact:
:: M & G Analyser Systems | Pune ::
Phone: +91 9822667465.
Kind Attn: Hemanth Krishna Martha,
VIETNAM:
REECO Science and Technology Co., Ltd.
Building A, Software Technology Park, Vo Truong Toan Street,
Vietnam National University, Quarter 6, Linh Trung Ward, Thu Duc City,
Ho Chi Minh City, Vietnam
Website:
Air quality monitoring equipment – Reeco (reecotech.com.vn)
Contact:
INDONESIA:
PT JJExotranoz Inter Vania
Jln. Raya Boulevard Q1 no. 5, Cibubur, Indonesia
Contact: Jefry KP
![]()
CHINA:
LICA United Technology Limited
The 5th.Building,No.18,Anningzhuang East Road
Haidian District, 100085, Beijing, China.
Website: LICA United Technology Limited (li-ca.com)
Airyx Products:
ICAD NO2 / NOx / NO Analyzer – Trace gas measurement
ICAD NO2 / NOx / NO分析仪 – 痕量气体测量 – 北京理加联合科技有限公司 (li-ca.com)
REPUBLIC OF KOREA:
Aireet Inc.
105-502 (5F), 16, Gakhwa-daero 69beon-gil, Buk-gu
Gwangju, Republic of Korea
Phone: +82 (0)10-9350-8148
Website: www.aireet.co.kr
Contact Person: Joonwoo Kim
RUSSIA AND CIS – (ARMENIA, AZERBAIJAN, BELARUS, KAZAKHSTAN, KYRGYZTAN, MOLDOVA, TAJIKISTAN, AND UZBEKISTAN):
Eniseylab Ltd
Russia, 660025, Krasnojarsk, Shelkovaya, 10, Room 102
Phone: +7 (391) 271-66-50
Contact Person: Dmitriy Zhiltsov
Website: www.eniseylab.ru