Airyx OPC‑UV3‑DL‑301 Open Path Ammonia Analyzer

Contact‑free NH₃ monitoring over 20–150 m open paths.

Principle of the Airyx OPC Open path DOAS instrument.

Description

The Airyx OPC‑UV3‑DL‑301 is an open path ammonia analyzer for contact‑free NH₃ monitoring. It measures along a free air beam over distances from 20 to 150 meters. As a result, it avoids sampling line losses and provides stable, path‑averaged concentration data.

Multi‑Path Operation

In addition, the system supports multi‑path operation. A motorized telescope head can redirect the beam between different retroreflectors. This enables spatially resolved ammonia measurements for agriculture, fence‑line monitoring and environmental air‑quality studies.

Furthermore, remote alignment shortens setup time. Consequently, operators can perform field tasks more efficiently. Therefore, the OPC‑UV3‑DL‑301 delivers reliable performance in real‑world conditions.

UV DOAS Technology

The OPC‑UV3‑DL‑301 uses UV DOAS with a stable deuterium lamp. In addition, the temperature‑stabilized spectrometer ensures long‑term stability. As a long‑path DOAS instrument, it eliminates sampling lines and minimizes NH₃ surface losses.

Key Features

Accurate gas detection

The OPC‑UV3‑DL‑301 measures NH₃, NO and SO₂ using UV DOAS. In addition, the open‑path design avoids sampling artefacts and ensures representative concentration data.

Compact and flexible operation

One analyzer can monitor several measurement paths through motorized beam routing. As a result, the system adapts well to different field setups and test layouts.

Rugged and mobile

The IP64 enclosure includes heating and dew‑point monitoring. Consequently, the analyzer performs reliably in challenging outdoor environments.

Fast and simple deployment

Motorized self‑alignment enables quick setup. Furthermore, only minimal on‑site adjustments are required.

Calibration‑free technology

UV DOAS does not require calibration gas bottles and shows no long‑term drift. Therefore, operational cost and maintenance remain low.

Applications

The OPC‑UV3‑DL‑301 open path ammonia analyzer supports a wide range of real‑world applications. In many cases, it improves measurement quality and reduces installation effort. For example, it is used in the following areas:

  • Air‑quality and workplace‑safety monitoring around ammonia sources
  • Agricultural NH₃ emission monitoring from barns, manure storage and fields
  • Industrial emission and process monitoring for NH₃ and related gases
  • Fence‑line monitoring at industrial or agricultural facilities
  • Spatial NH₃ mapping over open paths up to 150 m
  • Real‑time ammonia concentration measurement in dynamic outdoor environments

open path ammonia measurement principle with Airyx OPC‑UV3‑DL‑301

Frequently Asked Questions

What is an open path ammonia analyzer?

An open path ammonia analyzer measures NH₃ along a free air path between the instrument and a reflector. This contact‑free method avoids sampling losses. As a result, it provides representative average concentrations over distances from 20 to 150 meters.

Which gases can the OPC‑UV3‑DL‑301 detect?

It primarily measures NH₃ and can also detect NO and SO₂ using UV DOAS technology. Consequently, the system supports multiple gas‑related applications.

Where is the system used?

Typical applications include agricultural ammonia monitoring, fence‑line measurements, industrial emission control and environmental research. In addition, it is suitable for long‑term field campaigns.

Does the analyzer require calibration gases?

No. DOAS technology is calibration‑free and does not require calibration gas cylinders. Therefore, operation becomes simpler and long‑term cost is reduced.

What distances can it cover?

The system supports open‑path measurements between 20 and 150 meters. Furthermore, it maintains accurate alignment using a motorized telescope head and retroreflector setup.

Airyx OPC‑UV3‑DL‑301 open path NH3 analyzer in field application.

Optical and Measurement Specifications

These specifications describe the core optical setup and gas‑detection performance of the OPC‑UV3‑DL‑301 open path ammonia analyzer.

Parameter Specification
Optics Mirror telescope, 300 mm focal length
Detectable Gases NH₃, NO, SO₂
Limit of Detection
(at 100 m path length, 5 min averaging)
1 ppb (NH₃), 4 ppb (NO), 5.5 ppb (SO₂)
Path Length Up to 150 m (retroreflector)
Time Resolution Down to 1 minute
Compact Spectrometer 190–310 nm spectral range, temperature stabilized

Mechanical and System Specifications

The following parameters summarize the housing, system electronics and environmental design features relevant for field deployment.

Parameter Specification
Motorization Azimuth 0°–360°, Elevation −40° to 75°
Housing IP64, internal heating, dew‑point monitoring
Control Unit Integrated embedded PC (Windows 10 IoT)
Temperature Control Active heating & cooling
Additional Sensors Ambient temperature, pressure, housing dew point
Interfaces LAN, WiFi, internal storage
Power Supply / Consumption 24 V, max. 80 W

Interested in open‑path ammonia monitoring?
Contact us for a quote or technical consultation.

Get in Touch with Airyx

Find your local Airyx distributor or contact our Heidelberg team directly. Moreover, we support you with product questions, technical assistance and partnership inquiries.

Contact Airyx Headquarters

Airyx GmbH is based in Heidelberg, Germany. In addition, our team supports customers worldwide in environmental monitoring, wastewater emissions and air‑quality research.
Furthermore, we provide fast technical assistance and reliable guidance for instrument selection.

How to Reach Our Team

Email: info@airyx.de
Phone: +49 6221 9068977
Address:
Airyx GmbH
Hans‑Bunte‑Str. 4
69123 Heidelberg, Germany

If you need product information, quotations or technical assistance, please get in touch. As a result, you can rely on quick feedback when requesting quotations, technical details or product recommendations.

Send Us a Message

1 + 3 = ?

Find Your Local Distributor

Regional Expertise for DOAS and Gas‑Analysis Systems

Select your region below to find the appropriate Airyx distributor. As a result, you benefit from local expertise and shorter response times.

Europe

France


MEGATEC SAS
Saint-Aubin, France
Website: https://www.megatec.fr/
Contact: https://www.megatec.fr/contact
Contact person: Fabrice Losbar


Czech Republic, Slovakia & Lithuania


ENVItech Bohemia s.r.o.
Prague, Czech Republic
Website: https://www.envitech-bohemia.cz/
Contact: https://www.envitech-bohemia.cz/en/kontakt


Spain & Portugal


Green Light Research SLU
Madrid, Spain
Website: https://www.greenlightresearch.net/
Contact: https://www.greenlightresearch.net/contacto/


Italy


Luchsinger SRL
Curno, Italy
Website: https://www.luchsinger.it/
Contact: https://www.luchsinger.it/it/contatti/


Netherlands, Belgium, Luxembourg, Nordics


The Dutch Scientist
‘s‑Hertogenbosch, NL
Website: https://www.thedutchscientist.com/
Contact: https://www.thedutchscientist.com/CONTACT/


Finland


HNU Nordion
Helsinki, Finland
Website: https://hnunordion.fi/
Contact: https://hnunordion.fi/yhteystiedot/


Greece


Polaris Environment Ltd
Athens, Greece
Website: http://www.polaris-environment.gr/


Romania (ICAD only)


APEL LASER
Mogosoaia, Romania
Website: https://www.apellaser.ro/


Romania (Open Path, SkySpec, WGA)


PHANOS
Bucharest, Romania
Website: https://phanossci.com/


Bulgaria & Western Balkans


STABO‑Tech Ltd.
Stara Zagora, Bulgaria
Website: http://stabo-tech.eu/

Asia

India


M&G Analyzer Systems
Pune, India
Website: https://www.mganalyser.com/


Vietnam


Reeco Science & Technology Co.
Ho Chi Minh City, Vietnam
Website: https://reecotech.com.vn/


Indonesia


PT JJExotranoz Inter Vania
Cibubur, Indonesia
Contact: Jefry KP


China


Li‑Ca Scientific
Website: http://en.li-ca.com/

Additional Regional Availability

We also provide local support in Hong Kong, Macau and Taiwan through additional regional partners.

Global Distributor Network

Airyx works with a selected network of regional distributors who provide local expertise in air‑quality monitoring, DOAS‑based systems, wastewater gas analysis and real‑world emissions measurement.

Worldwide Coverage at a Glance

Airyx international distributor and partner map

Your Nearest Airyx Partner

Need Technical Support?

Get Fast Assistance from Our Technical Specialists

If you need troubleshooting, data interpretation or guidance for your emissions‑monitoring setup, our technical team is ready to assist you.

Explore Airyx Products